PA control boxes use LED indicators to communicate status and fault conditions. LED patterns vary by model — this article covers the most common codes for the PA-20, PA-22, PA-24, and FLTCON series.

PA-20 / PA-22 / PA-24 LED Codes

LED Colour / Pattern Meaning Action
Green steady Powered and ready Normal — no action needed
Green flashing Motor running Normal during motion
Red steady Overcurrent / overload protection tripped Remove load, allow to cool, check rated load vs actual load
Red flashing (slow) Thermal protection tripped Power off for 10–15 min, ensure ambient temperature is within spec
Red flashing (fast) Short circuit detected on output Check actuator wiring for bare wires touching; inspect actuator motor for internal short
No LED No power to control box Check input power, inline fuse, and power supply output voltage

FLTCON Series LED Codes

LED Pattern Meaning Action
Blue steady Powered, no motion commanded Normal standby
Blue flashing Motor running, Hall feedback active Normal during motion
Red (one channel) Feedback signal lost on that channel Check Hall effect sensor wiring; verify actuator is a PA-04-HS or custom Hall effect model
Red alternating channels Synchronisation error — channels too far apart Stop, manually re-home both actuators to the same position, then restart
Orange / amber Input voltage outside operating range Verify AC mains voltage; check for voltage drop on extension cord

 

💡 Model-specific codes Always cross-reference with your specific model's user manual, available on the PA Resources page. LED code meanings can vary between hardware revisions.